+61 2 9669 4000
Unit 19, 77 Bourke Road, Alexandria, NSW 2015 AUSTRALIA

Comet System – Data Loggers, Transmitters & Regulators

Data Logger, Transmitters & Regulators

CMC provides Comet SRO Relative Humidity, Temperature, Atmospheric Pressure, Carbon Dioxide and Flood Control loggers, transmitters and regulators.

P8652
u4440 Comet
T2514
T2118 2218

Flood Detector Loggers

U3832g Comet Flood Detector

IoT Wireless Temperature and Relative Humidity Datalogger with flood detector, with built-in 4G modem

  • Usage: Intended for indoor usage only
  • Cable length: 2.5 meters (can`t be extended)
  • Connection: via ELKA connector, powered directly from U3832G
P8653 Comet Flood Detector

Web Sensor with PoE – two channels with flood detector and binary inputs

  • Usage: Intended for indoor usage only
  • Cable length: 2.5 meters (can`t be extended)
  • Two wire connection: red wire – active, black wire – GND, directly powered from P8653

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Atmospheric Pressure Data Loggers

T2114 2214 2314

T2114 Barometric pressure transmitter – 4-20mA output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2118 2218

T2118 Interior barometer with 4-20mA output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2114 2214 2314

T2214 Barometric pressure transmitter – 0-10V output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2118 2218

T2218 Interior barometer with 0-10V output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2114 2214 2314

T2314 Barometric pressure transmitter – RS232 output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2414

T2414 Barometric pressure transmitter – RS485 interface

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2514

Web Sensor T2514 – remote barometer with Ethernet interface

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
Datalogger for external CO2 probe up to 50.000 ppm with built-in atmospheric pressure sensor

U2422 Datalogger for external CO2 probe up to 50.000 ppm with built-in atmospheric pressure sensor

  • Measuring range: 700 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
u4440 Comet

U4440- Temperature, humidity, CO2 and atmospheric pressure data logger with built-in sensors

  • Measuring range: 700 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
u7844 Comet

U7844 Four-channel data logger with pulse and two-state inputs

  • Two-state signal
  • Pulses

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Relative Humidity, Temperature Transmitters and Regulators

H3020

H3020 temperature and humidity regulator

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3021

H3021 temperature and humidity regulator

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3021p

H3021P compressed air temperature and humidity regulator

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3060

H3060 temperature and humidity regulator with 230Vac/8A relays, humidistat

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3061

H3061 temperature and humidity regulator with 230Vac/8A relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3061p

H3061P compressed air temperature and humidity regulator with 230Vac/8A relays

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3331

H3331 temperature and humidity regulator with RS232 output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3430

H3430 temperature and humidity regulator with RS485 output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3431

H3431 temperature and humidity regulator with RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3530

H3530 – thermometer hygrometer with Ethernet interface and relays, humidistat

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531

H3531 – thermometer hygrometer with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531p

H3531P – compressed-air thermometer hygrometer with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531r Big 1 4531r 7531r

H3531R – rack mount thermometer hygrometer with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
P8511

Web Sensor P8511 – one channel remote thermometer hygrometer

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx
  • Accuracy: according to the connected probe DSxx
P3110e

P1110E Economy humidity and temperature transmitter with 4-20mA outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.6 °C; ±3 % RH from 5 to 95 % at 23 °C
P3116

P3116 Economy humidity and temperature transmitter with external interchangeable probe, 4-20mA outputs

  • Measuring range: -20 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±1.8 % RH from 0 to 90 % at 23 °C
P8541

Web Sensor P8541 – four channels remote thermometer hygrometer

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx
  • Accuracy: according to the connected probe DSxx
P8552 8652

Web Sensor P8552 – two channels with binary inputs

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx
  • Accuracy: according to the connected probe DSxx
P8641

Web Sensor P8641 with PoE – four channels remote thermometer hygrometer

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx
  • Accuracy: according to the connected probe DSxx
P8652

Web Sensor P8652 with PoE – two channels with binary inputs

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx
  • Accuracy: according to the connected probe DSxx
T0210

T0210 Temperature and humidity outdoor, indoor probe with 0-10V output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0211

T0211 Temperature and humidity probe with 1m cable and 0-10V output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111p 0211p

T0211P Compressed air RH+T+Tdp sensor with 1m cable and 0-10V output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0213

T0213 Temperature and humidity duct probe with 0-10V output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0213d

T0213D Temperature and humidity duct probe with 0-10V output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T1110 3110

T3110 Temperature and humidity outdoor, indoor probe with 4-20mA output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3110ex

T3110Ex Intrinsically safe humidity and temperature transmitter with 4-20mA output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111

T3111 RH+T+Tdp cable probe, 1m cable length, output 4-20mA

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111ex

T3111Ex Intrinsically safe humidity and temperature transmitter with cable probe, 1m cable length, output 4-20mA

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111p 0211p

T3111P Compressed air RH+T+Tdp sensor with 4-20mA output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113 3313

T3113 Temperature and humidity duct probe with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113d

T3113D Temperature and humidity duct probe with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113ex

T3113Ex Intrinsically safe humidity and temperature duct transmitter with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3117

T3117 Temperature and humidity bar type probe with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3118 3218 3318 3418

T3118 Interior temperature, humidity transmitter with 4-20mA output

  • Measuring range: -10 to +50 °C; 5 to 95% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3118 3218 3318 3418

T3218 Interior temperature, humidity transmitter with 0-10V output

  • Measuring range: -10 to +50 °C; 5 to 95% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3311

T3311 Temperature and humidity probe with RS232 output, internal sensors

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3313

T3313 Temperature and humidity probe with RS232 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3118 3218 3318 3418

T3318 Interior temperature, humidity transmitter with RS232 output (Discontinued, Replaced by T3418)

  • Measuring range: -10 to +50 °C; 5 to 95% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3319

T3319 Industrial temperature and humidity transmitter – RS232 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3411

T3411 RH+T+Tdp outdoor, indoor probe, RS485 interface

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3413

T3413 Temperature and humidity duct mount transmitter with RS485 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3413d

T3413D Temperature and humidity duct mount transmitter with RS485 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3417

T3417 Temperature and humidity bar type transmitter with RS485 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3118 3218 3318 3418

T3418 Interior temperature, humidity transmitter with RS485 output

  • Measuring range -10 to +50 °C; 5 to 95 % RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 65 %
T3419

T3419 Temperature and humidity transmitter with external probe – RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3411p 3419p

T3419P Compressed air RH+T transmitter with RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3510

Web Sensor T3510 – remote thermometer hygrometer with Ethernet interface

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.6 °C; ±2.5 % RH from 5 to 95 %
T3511 7511

Web sensor T3511 – remote thermometer hygrometer with Ethernet interface

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3511p

Web sensor T3511P – compressed air remote thermometer hygrometer with Ethernet interface

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3610 7610

Web Sensor T3610 with PoE – remote thermometer hygrometer with Ethernet interface

  • Measuring range: -20 to +60 °C; 0 to 100% RH
  • Accuracy: ±0.6 °C; ±2.5 % RH from 5 to 95 %
T3611 7611

Web Sensor T3611 with PoE – remote thermometer hygrometer with Ethernet interface

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Relative Humidity, Temperature and Atmospheric Pressure

H7430

H7430 temperature, humidity, pressure regulator with two relay and RS485 outputs

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7431

H7431 temperature, humidity, pressure regulator with two relay and RS485 outputs (Discontinued Model)

  • Measuring range: Unavailable
  • Accuracy: Unavailable
H7530

H7530 – thermometer hygrometer barometer with Ethernet interface and relays

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7531

H7531 – thermometer hygrometer barometer with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H3531r Big 1 4531r 7531r

H7531R temperature, humidity and barometric pressure rack mount monitor (Discontinued Model)

  • Measuring range: Unavailable
  • Accuracy: Unavailable
T7310

T7310 Industrial temperature, humidity, bar. pressure transmitter – RS232 output

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7311

T7311 Industrial temperature, humidity, bar. pressure transmitter – RS232 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7318 7418

T7318 Interior temperature, humidity, bar. pressure transmitter – RS232 output (Discontinued, Replaced by T3418)

  • Measuring range: -10 to +50 °C; 0 to 100% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
Comet Data Logger

T7410 Industrial temperature, humidity, bar. pressure transmitter – RS485 output

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
Comet Data Logger Rs485 Output

T7411 Industrial temperature, humidity, bar. pressure transmitter – RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7318 7418

T7418 Interior temperature, humidity, bar. pressure transmitter – RS485 output

  • Measuring range: -10 to +50 °C; 0 to 100% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3510 7510

Web Sensor T7510 – remote thermometer hygrometer barometer with Ethernet interface

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.6 °C; ±2.5 % RH from 5 to 95 %
T3511 7511

Web Sensor T7511 – remote thermometer hygrometer barometer with Ethernet interface

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3610 7610

Web Sensor T7610 with PoE – remote thermometer hygrometer barometer with Ethernet interface

  • Measuring range: -20 to +60 °C; 0 to 100% RH
  • Accuracy: ±0.6 °C; ±2.5 % RH from 5 to 95 %
T7611

Web Sensor T7611 with PoE – remote thermometer hygrometer barometer with Ethernet interface

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Temperature Transmitters and Regulators

H0430

H0430 temperature transmitter and regulator with RS485 output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
H0530

H0530 – thermometer with Ethernet interface and relays

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
H4331 4431

H4331 Temperature transmitter with RS232 output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
H4331 4431

H4431 Temperature transmitter with RS485 output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
H4531

H4531 – thermometer with Ethernet interface and relays

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
H3531r Big 1 4531r 7531r

H4531R – rack mount thermometer with Ethernet interface and relays

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
Comet Temperature Sensor With 4 20ma Output

P0120 – Remote temperature sensor with 4-20mA output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
P0132

P0132 – Duct mount temperature probe 0 to +150°C, IP65

  • Measuring range: 0 to +150 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4121 Temperature Transmitter Pt1000 -30°C to +80°C/ 4 to 20 mA

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4131 Temperature Transducer Pt1000 0°C to +150°C/ 4 to 20 mA

  • Measuring range: 0 to +150 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4141 Temperature Transducer Pt1000 -100°C to +30°C/ 4 to 20 mA

  • Measuring range: -100 to +30 °C
  • Accuracy: ±0.3 °C
Comet Temperature Transmitter Pt1000

P4151 Temperature Transducer Pt1000 0°C to +35°C/ 4 to 20 mA

  • Measuring range: 0 to +35 °C
  • Accuracy: ±0.2 °C
Comet Temperature Transmitter Pt1000

P4161 Temperature Transducer Pt1000 0°C to +250°C/ 4 to 20 mA

  • Measuring range: 0 to +250 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4171 Temperature Transducer Pt1000 0°C to +400°C/ 4 to 20 mA

  • Measuring range: 0 to +400 °C
  • Accuracy: ±0.7 °C
Comet Temperature Transmitter Pt1000

P4191 Temperature Transducer Pt1000 -50°C to +50°C/ 4 to 20 mA

  • Measuring range: -50 to +50 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P6181 Temperature Transducer Pt100 -100°C to +200°C/ 4 to 20 mA

  • Measuring range: -100 to +200 °C
  • Accuracy: ±0.3°C up to +100°C, ±0.4°C over +100°C
P8510

Web Sensor P8510 – remote thermometer

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.8 °C in the range teplot od -10 °C do +80°C; ±2,0 °C in the range teplot od -10 °C do -30 °C
P8511

Web Sensor P8511 – one channel remote thermometer hygrometer

  • Measuring range: -55 to +105 °C
  • Accuracy: according to the connected probe DSxx
P8541

Web Sensor P8541 – four channels remote thermometer hygrometer

  • Measuring range: -55 to +105 °C
  • Accuracy: according to the connected probe DSxx
P8610

Web Sensor P8610 with PoE – remote thermometer

  • Measuring range: -20 to +60 °C
  • Accuracy: ±0.8 °C in the range teplot od -10 °C do +80°C; ±2,0 °C in the range teplot od -10 °C do -30 °C
P8641

Web Sensor P8641 with PoE – four channels remote thermometer hygrometer

  • Measuring range: -55 to +105 °C
  • Accuracy: according to the connected probe DSxx
T0110

T0110 Temperature transmitter outdoor, indoor with 4-20mA output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
T0118 0218 0318 0418

T0118 Interior temperature transmitter with 4-20mA output

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0118 0218 0318 0418

T0218 Interior temperature transmitter with 0-10V output

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0310

T0310 Temperature transmitter with RS232 output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
T0118 0218 0318 0418

T0318 Interior temperature transmitter with RS232 output (Discontinued, Replaced by T0418)

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0410

T0410 Temperature transmitter with RS485 output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
T0118 0218 0318 0418

T0418 Interior temperature transmitter with RS485 output

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0410

Web sensor T0510 – remote thermometer with Ethernet interface

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.6 °C
T0610

Web Sensor T0610 with PoE – remote thermometer with Ethernet interface

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.6 °C
T4111

T4111 Temperature transmitter with 4-20mA output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.15°C plus 0.1% from adjusted output span (without temperature probe)
T4111

T4211 Temperature transmitter with 0-10V output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.15°C plus 0.1% from adjusted output span (without temperature probe)
T4311

T4311 Temperature transmitter with RS232 interface

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2°C (without temperature probe)
T4411

T4411 Temperature transmitter with RS485 interface

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2°C (without temperature probe)
T4511

Web sensor T4511 – remote thermometer with Ethernet interface

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2°C
T4611

Web Sensor T4611 with PoE – remote thermometer with Ethernet interface

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2°C

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Carbon Dioxide Transmitters and Regulators

H5021 5321 5421 5521

H5021 CO2 concentration transmitter with two relay outputs

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5024

H5024 CO2 concentration transmitter with two relay outputs

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5021 5321 5421 5521

H5321 CO2 concentration transmitter with RS232 and two relay outputs

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5324 5424

H5324 CO2 concentration transmitter with RS232 and two relay outputs

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5021 5321 5421 5521

H5421 CO2 concentration transmitter with RS485 and two relay outputs

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5324 5424

H5424 CO2 concentration transmitter with RS485 and two relay outputs

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5521

H5521 – remote CO2 concentration with Ethernet interface and two relays

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5524

H5524 – remote CO2 concentration with Ethernet interface and two relays

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5140

T5140 CO2 concentration transmitter with 4-20mA output, built-in carbon dioxide sensor

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5141 CO2 concentration transmitter with 4-20mA output, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

T5240 CO2 concentration transmitter with 0-10V output, built-in carbon dioxide sensor

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5241 CO2 concentration transmitter with 0-10V output, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

T5340 CO2 concentration transmitter with RS232 interface, internal carbon dioxide sensor

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5341 CO2 concentration transmitter with RS232 interface, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

T5440 CO2 concentration transmitter with RS485 interface

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5441 CO2 concentration transmitter with RS485 interface, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

Web sensor T5540 – remote CO2 concentration with Ethernet interface

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

Web Sensor T5541 – remote CO2 concentration with Ethernet interface

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Carbon Dioxide, Relative Humidity and Temperature

H6020

H6020 Temperature, humidity, CO2 transmitter with two relay outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6320 6420

H6320 Temperature, humidity, CO2 transmitter with two relay and RS232 outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6320 6420

H6420 Temperature, humidity, CO2 transmitter with two relay and RS485 outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6520

H6520 – remote CO2 concentration thermometer hygrometer with Ethernet interface and two relays

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6340

T6340 Temperature, humidity, CO2 transmitter with RS232 interface

  • Measuring range: -10 to +50 °C; 5 to 95 % RH; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6340

T6440 Temperature, humidity, CO2 transmitter with RS485 interface

  • Measuring range: -10 to +50 °C; 5 to 95 % RH; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6340

Web sensor T6540 – remote CO2 concentration thermometer hygrometer with Ethernet interface

  • Measuring range: -30 to +80 °C; 5 to 95 % RH; 0 to 2000 ppm
  • Accuracy: ±0.6 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Carbon Dioxide and Temperature

T8148 8248 8448

T8148 CO2 concentration and temperature transmitter with 4-20mA outputs, built-in sensors

  • Measuring range: -10 to +50 °C; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T8148 8248 8448

T8248 CO2 concentration and temperature transmitter with 0-10V outputs, built-in sensors

  • Measuring range: -10 to +50 °C; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T8148 8248 8448

T8448 CO2 concentration and temperature transmitter with RS485 output, built-in sensors

  • Measuring range: -10 to +50 °C; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Current Transmitters and Regulators

P2520a

Web Sensor P2520 – two channel remote 0-20mA inputs

  • Measuring range: Current
  • Accuracy: ±0.1% FS od 0 °C do +50 °C, ±0.3% FS od -30 °C do +80 °C

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Temperature, Relative Humidity And Two-State Signals

P8552 8652

Web Sensor P8552 – two channels with binary inputs

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx, Two-state signals
  • Accuracy: according to the connected probe DSxx
P8552 8652

Web Sensor P8652 with PoE – two channels with binary inputs

  • Measuring range: -55 to +105 °C; according to the connected probe DSxx, Two-state signals
  • Accuracy: according to the connected probe DSxx

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Solar Radiation Shields

8100 02

COMETEO Professional Thermometer Screen for Weather Station Sensor (This model replaced F8100 & F8200)

  • Temperature operating range: -40 to +65 °C
  • Relative humidity operating range: 0 to 100 %RH

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!