Mass Flow Meter With Certified Accuracy With Low Pressure Drop Of Gases, Liquids And Steam
SKI AccuFlo® LPD is a high-accuracy mass flow metre designed for accounting and fiscal transfer measurements, as well as applications requiring extreme mechanical loads.
AccuFlo® LPD Mass flow meter
The AccuFlo® LPD is optimally tailored to the specific measuring task. Its “plug-and-play” design allows for easy installation and commissioning.
It is traceable to international standards and provides unique operational reliability based on an approved body’s water calibration certificate issued by a laboratory (an ISO 17025 laboratory or a legal metrology office). Disputes over energy quality, mass accounts, and balances are no longer relevant.
The AccuFlo® LPD is ideal for accurate, traceable measurements outside the jurisdiction of the measurement instrument directive, providing a reliable, “Plug-and-Play” solution that performs well in harsh conditions, withstands pipe vibrations, and minimizes permanent pressure losses.
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Technical specification Of AccuFlo® LPD
- Measured Quantity: Flow (as volume flow, mass flow, standardized volume flow, transferred heat or velocity); Absolute Pressure; Temperature
- Measured Fluid: Gases (with dust, water saturated, corrosive); Liquids (low viscosity); Steam (saturated and superheated)
- Temperature Range: Standard: −50 … 450 °C, optional up to 500 °C
- Pressure Range: Standard: PN10 to PN100 (AISI Class 150 to AISI Class 600); Higher pressure ratings upon request
- Diameter Range: DN 25 to DN 300; 1″ to 12″ (larger diameters upon request)
- Required Straight Inlet and Outlet Pipe Runs: Standard: 7xD inlet, 3xD outlet (partial straight inlet and outlet pipe run are already included in the device)
- Material: Flow sensor: 1.4404 (AISI 316L) or 1.5415 (ASTM A335 Grade P1/F1); Pipe section: 1.0345 (P235GH, ASTM A 105/106), 1.4404 (AISI 316L) or 1.5415 (ASTM A335/A 182 Grade P1/F1)
- Measurement Range: 1:7, optional 1:40
- Error Limit: ±0.6 % of mass flow in the calibrated range
- Zero Point Error: ±0.07 % of full scale in the calibrated range
- Flow Computer: For panel or wall mounting; TFT color display with touch screen; 2 analog outputs (0)4 … 20 mA; 3 switching outputs (freely selectable function incl. alarm); Fieldbuses (Modbus; Profibus/Profinet in preparation); Auxiliary power 90 … 250 V AC or 18 … 36 V DC
WANT MORE TECHNICAL DETAILS? DOWNLOAD OUR DATASHEET.
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!