Mass Flow Meter With Certified Accuracy With Low Pressure Drop Of Gases, Liquids And Steam

SKI AccuFlo® LPD is a high-accuracy mass flow metre designed for accounting and fiscal transfer measurements, as well as applications requiring extreme mechanical loads.

Ski Accuflo Lpd Mass Flow Meter Cmc
Ski Accuflo® Lpd Mass Flow Meter Cmc
Ski Accuflo® Lpd Mass Flow Meter Cmc
Ski Accuflo Lpd Mass Flow Meter Cmc

AccuFlo® LPD Mass flow meter

The AccuFlo® LPD is optimally tailored to the specific measuring task. Its “plug-and-play” design allows for easy installation and commissioning.

It is traceable to international standards and provides unique operational reliability based on an approved body’s water calibration certificate issued by a laboratory (an ISO 17025 laboratory or a legal metrology office). Disputes over energy quality, mass accounts, and balances are no longer relevant.

The AccuFlo® LPD is ideal for accurate, traceable measurements outside the jurisdiction of the measurement instrument directive, providing a reliable, “Plug-and-Play” solution that performs well in harsh conditions, withstands pipe vibrations, and minimizes permanent pressure losses.

Ski Accuflo Lpd Mass Flow Meter Cmc

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Technical specification Of AccuFlo® LPD

Ski Accuflo® Lpd Mass Flow Meter Cmc
  • Measured Quantity: Flow (as volume flow, mass flow, standardized volume flow, transferred heat or velocity); Absolute Pressure; Temperature
  • Measured Fluid: Gases (with dust, water saturated, corrosive); Liquids (low viscosity); Steam (saturated and superheated)
  • Temperature Range: Standard: −50 … 450 °C, optional up to 500 °C
  • Pressure Range: Standard: PN10 to PN100 (AISI Class 150 to AISI Class 600); Higher pressure ratings upon request
  • Diameter Range: DN 25 to DN 300; 1″ to 12″ (larger diameters upon request)
  • Required Straight Inlet and Outlet Pipe Runs: Standard: 7xD inlet, 3xD outlet (partial straight inlet and outlet pipe run are already included in the device)
  • Material: Flow sensor: 1.4404 (AISI 316L) or 1.5415 (ASTM A335 Grade P1/F1); Pipe section: 1.0345 (P235GH, ASTM A 105/106), 1.4404 (AISI 316L) or 1.5415 (ASTM A335/A 182 Grade P1/F1)
  • Measurement Range: 1:7, optional 1:40
  • Error Limit: ±0.6 % of mass flow in the calibrated range
  • Zero Point Error: ±0.07 % of full scale in the calibrated range
  • Flow Computer: For panel or wall mounting; TFT color display with touch screen; 2 analog outputs (0)4 … 20 mA; 3 switching outputs (freely selectable function incl. alarm); Fieldbuses (Modbus; Profibus/Profinet in preparation); Auxiliary power 90 … 250 V AC or 18 … 36 V DC