Comet Transmitters And Regulators

CMC provides Comet SRO transmitters and regulators for the measurement of Relative Humidity, Temperature, Atmospheric Pressure, and Carbon Dioxide.

P8652
Comet Temperature Transmitter Pt1000
T2514
T2118 2218

Atmospheric Pressure Transmitters

T2114 2214 2314

T2114 Barometric Pressure Transmitter – 4-20mA Output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2118 2218

T2118 Interior Barometer Transmitter with 4-20mA Output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2114 2214 2314

T2214 Barometric Pressure Transmitter – 0-10V Output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2118 2218

T2218 Interior Barometer Transmitter with 0-10V Output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2114 2214 2314

T2314 Barometric Pressure Transmitter – RS232 Output

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2414

T2414 Barometric Pressure Transmitter – RS485 Interface

  • Measuring range: 600 to 1100 hPa
  • Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Relative Humidity, Temperature Transmitters and Regulators

H3020

H3020 temperature and humidity regulator

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3021

H3021 temperature and humidity regulator

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3021p

H3021P compressed air temperature and humidity regulator

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3060

H3060 temperature and humidity regulator with 230Vac/8A relays, humidistat

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3061

H3061 temperature and humidity regulator with 230Vac/8A relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3061p

H3061P compressed air temperature and humidity regulator with 230Vac/8A relays

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3331

H3331 temperature and humidity regulator with RS232 output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3430

H3430 temperature and humidity regulator with RS485 output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3431

H3431 temperature and humidity regulator with RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3530

H3530 – thermometer hygrometer regulator with Ethernet interface and relays, humidistat

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531

H3531 – thermometer hygrometer regulator with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531p

H3531P – compressed-air thermometer hygrometer regulator with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531r Big 1 4531r 7531r

H3531R – rack mount thermometer hygrometer regulator with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3411p 3419p

T3419P Compressed air RH+T transmitter with RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
P3110e

P1110E Economy humidity and temperature transmitter with 4-20mA outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.6 °C; ±3 % RH from 5 to 95 % at 23 °C
P3116

P3116 Economy humidity and temperature transmitter with external interchangeable probe, 4-20mA outputs

  • Measuring range: -20 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±1.8 % RH from 0 to 90 % at 23 °C
T0210

T0210 Temperature and humidity transmitter outdoor, indoor probe with 0-10V output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0211

T0211 Temperature and humidity transmitter probe with 1m cable and 0-10V output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111p 0211p

T0211P Compressed air RH+T+Tdp transmitter with 1m cable and 0-10V output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0213

T0213 Temperature and humidity transmitter duct probe with 0-10V output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0213d

T0213D Temperature and humidity transmitter duct probe with 0-10V output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T1110 3110

T3110 Temperature and humidity transmitter outdoor, indoor probe with 4-20mA output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3110ex

T3110Ex Intrinsically safe humidity and temperature transmitter with 4-20mA output

  • Measuring range: -30 to +80 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111

T3111 transmitter RH+T+Tdp cable probe, 1m cable length, output 4-20mA

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111ex

T3111Ex Intrinsically safe humidity and temperature transmitter with cable probe, 1m cable length, output 4-20mA

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111p 0211p

T3111P transmitter compressed air RH+T+Tdp sensor with 4-20mA output

  • Measuring range: -30 to +105 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113 3313

T3113 Temperature and humidity transmitter duct probe with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113d

T3113D Temperature and humidity transmitter duct probe with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113ex

T3113Ex Intrinsically safe humidity and temperature transmitter duct transmitter with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3117

T3117 Temperature and humidity transmitter bar type probe with 4-20mA output

  • Measuring range: -30 to +125 °C; 0 to 100 % RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3118 3218 3318 3418

T3118 Interior temperature, humidity transmitter with 4-20mA output

  • Measuring range: -10 to +50 °C; 5 to 95% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3118 3218 3318 3418

T3218 Interior temperature, humidity transmitter with 0-10V output

  • Measuring range: -10 to +50 °C; 5 to 95% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3311

T3311 Temperature and humidity transmitter probe with RS232 output, internal sensors

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3313

T3313 Temperature and humidity transmitter probe with RS232 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3118 3218 3318 3418

T3318 Interior temperature, humidity transmitter with RS232 output (Discontinued, Replaced by T3418)

  • Measuring range: -10 to +50 °C; 5 to 95% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3319

T3319 Industrial temperature and humidity transmitter – RS232 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3411

T3411 RH+T+Tdp outdoor, indoor transmitter probe, RS485 interface

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3413

T3413 Temperature and humidity duct mount transmitter with RS485 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3413d

T3413D Temperature and humidity duct mount transmitter with RS485 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3417

T3417 Temperature and humidity bar type transmitter with RS485 output

  • Measuring range: -30 to +125 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3118 3218 3318 3418

T3418 Interior temperature, humidity transmitter with RS485 output

  • Measuring range -10 to +50 °C; 5 to 95 % RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 65 %
T3419

T3419 Temperature and humidity transmitter with external probe – RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3411p 3419p

T3419P Compressed air RH+T transmitter with RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Relative Humidity, Temperature and Atmospheric Pressure Transmitters And Regulators

H7430

H7430 temperature, humidity, pressure regulator with two relay and RS485 outputs

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7431

H7431 temperature, humidity, pressure regulator with two relay and RS485 outputs (Discontinued Model)

  • Measuring range: Unavailable
  • Accuracy: Unavailable
H7530

H7530 – thermometer hygrometer barometer regulator with Ethernet interface and relays

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7531

H7531 – thermometer hygrometer barometer regulator with Ethernet interface and relays

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H3531r Big 1 4531r 7531r

H7531R temperature, humidity and barometric pressure rack mount monitor (Discontinued Model)

  • Measuring range: Unavailable
  • Accuracy: Unavailable
T7310

T7310 Industrial temperature, humidity, bar. pressure transmitter – RS232 output

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7311

T7311 Industrial temperature, humidity, bar. pressure transmitter – RS232 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7318 7418

T7318 Interior temperature, humidity, bar. pressure transmitter – RS232 output (Discontinued, Replaced by T3418)

  • Measuring range: -10 to +50 °C; 0 to 100% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
Comet Data Logger

T7410 Industrial temperature, humidity, bar. pressure transmitter – RS485 output

  • Measuring range: -30 to +80 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
Comet Data Logger Rs485 Output

T7411 Industrial temperature, humidity, bar. pressure transmitter – RS485 output

  • Measuring range: -30 to +105 °C; 0 to 100% RH
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7318 7418

T7418 Interior temperature, humidity, bar. pressure transmitter – RS485 output

  • Measuring range: -10 to +50 °C; 0 to 100% RH
  • Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Temperature Transmitters and Regulators

H0430

H0430 temperature transmitter and regulator with RS485 output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
H0530

H0530 – thermometer transmitter with Ethernet interface and relays

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
H4331 4431

H4331 Temperature transmitter with RS232 output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
H4331 4431

H4431 Temperature transmitter with RS485 output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
H4531

H4531 – thermometer transmitter with Ethernet interface and relays

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
H3531r Big 1 4531r 7531r

H4531R – rack mount thermometer with Ethernet interface and relays

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2 °C
Comet Temperature Sensor With 4 20ma Output

P0120 – Remote temperature sensor transmitter with 4-20mA output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
P0132

P0132 – Duct mount temperature transmitter probe 0 to +150°C, IP65

  • Measuring range: 0 to +150 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4121 Temperature Transmitter Pt1000 -30°C to +80°C/ 4 to 20 mA

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4131 Temperature transmitter Transducer Pt1000 0°C to +150°C/ 4 to 20 mA

  • Measuring range: 0 to +150 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4141 Temperature transmitter Transducer Pt1000 -100°C to +30°C/ 4 to 20 mA

  • Measuring range: -100 to +30 °C
  • Accuracy: ±0.3 °C
Comet Temperature Transmitter Pt1000

P4151 Temperature transmitter Transducer Pt1000 0°C to +35°C/ 4 to 20 mA

  • Measuring range: 0 to +35 °C
  • Accuracy: ±0.2 °C
Comet Temperature Transmitter Pt1000

P4161 Temperature transmitter Transducer Pt1000 0°C to +250°C/ 4 to 20 mA

  • Measuring range: 0 to +250 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P4171 Temperature transmitter Transducer Pt1000 0°C to +400°C/ 4 to 20 mA

  • Measuring range: 0 to +400 °C
  • Accuracy: ±0.7 °C
Comet Temperature Transmitter Pt1000

P4191 Temperature Transmitter Transducer Pt1000 -50°C to +50°C/ 4 to 20 mA

  • Measuring range: -50 to +50 °C
  • Accuracy: ±0.4 °C
Comet Temperature Transmitter Pt1000

P6181 Temperature Transmitter Transducer Pt100 -100°C to +200°C/ 4 to 20 mA

  • Measuring range: -100 to +200 °C
  • Accuracy: ±0.3°C up to +100°C, ±0.4°C over +100°C
T0110

T0110 Temperature transmitter outdoor, indoor with 4-20mA output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
T4411

T4411 Temperature transmitter with RS485 interface

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2°C (without temperature probe)
T0118 0218 0318 0418

T0118 Interior temperature transmitter with 4-20mA output

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0118 0218 0318 0418

T0218 Interior temperature transmitter with 0-10V output

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0310

T0310 Temperature transmitter with RS232 output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
T0118 0218 0318 0418

T0318 Interior temperature transmitter with RS232 output (Discontinued, Replaced by T0418)

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T0410

T0410 Temperature transmitter with RS485 output

  • Measuring range: -30 to +80 °C
  • Accuracy: ±0.4 °C
T0118 0218 0318 0418

T0418 Interior temperature transmitter with RS485 output

  • Measuring range: -10 to +50 °C
  • Accuracy: ±0.5 °C
T4111

T4111 Temperature transmitter with 4-20mA output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.15°C plus 0.1% from adjusted output span (without temperature probe)
T4111

T4211 Temperature transmitter with 0-10V output

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.15°C plus 0.1% from adjusted output span (without temperature probe)
T4311

T4311 Temperature transmitter with RS232 interface

  • Measuring range: -200 to +600 °C
  • Accuracy: ±0.2°C (without temperature probe)

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Carbon Dioxide Transmitters and Regulators

H5021 5321 5421 5521

H5021 CO2 concentration transmitter with two relay outputs

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5024

H5024 CO2 concentration transmitter with two relay outputs

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5021 5321 5421 5521

H5321 CO2 concentration transmitter with RS232 and two relay outputs

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5324 5424

H5324 CO2 concentration transmitter with RS232 and two relay outputs

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5021 5321 5421 5521

H5421 CO2 concentration transmitter with RS485 and two relay outputs

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5324 5424

H5424 CO2 concentration transmitter with RS485 and two relay outputs

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5521

H5521 – remote Transmitter CO2 concentration with Ethernet interface and two relays

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5524

H5524 – remote Transmitter CO2 concentration with Ethernet interface and two relays

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5140

T5140 CO2 concentration transmitter with 4-20mA output, built-in carbon dioxide sensor

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5141 CO2 concentration transmitter with 4-20mA output, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

T5240 CO2 concentration transmitter with 0-10V output, built-in carbon dioxide sensor

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5241 CO2 concentration transmitter with 0-10V output, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

T5340 CO2 concentration transmitter with RS232 interface, internal carbon dioxide sensor

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5341 CO2 concentration transmitter with RS232 interface, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5140

T5440 CO2 concentration transmitter with RS485 interface

  • Measuring range: 0 to 2000 ppm
  • Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141

T5441 CO2 concentration transmitter with RS485 interface, external carbon dioxide probe, 1m cable

  • Measuring range: 0 to 10 000 ppm
  • Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Carbon Dioxide, Relative Humidity and Temperature Transmitters

H6020

H6020 Temperature, humidity, CO2 transmitter with two relay outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6320 6420

H6320 Temperature, humidity, CO2 transmitter with two relay and RS232 outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6320 6420

H6420 Temperature, humidity, CO2 transmitter with two relay and RS485 outputs

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6520

H6520 – remote Transmitter CO2 concentration thermometer hygrometer with Ethernet interface and two relays

  • Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
  • Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6340

T6340 Temperature, humidity, CO2 transmitter with RS232 interface

  • Measuring range: -10 to +50 °C; 5 to 95 % RH; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6340

T6440 Temperature, humidity, CO2 transmitter with RS485 interface

  • Measuring range: -10 to +50 °C; 5 to 95 % RH; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa

INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!

Carbon Dioxide and Temperature Transmitters

T8148 8248 8448

T8148 CO2 concentration and temperature transmitter with 4-20mA outputs, built-in sensors

  • Measuring range: -10 to +50 °C; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T8148 8248 8448

T8248 CO2 concentration and temperature transmitter with 0-10V outputs, built-in sensors

  • Measuring range: -10 to +50 °C; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T8148 8248 8448

T8448 CO2 concentration and temperature transmitter with RS485 output, built-in sensors

  • Measuring range: -10 to +50 °C; 0 to 2000 ppm
  • Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa