Celebrating 25 Years 1999-2024
Comet Transmitters And Regulators
CMC provides Comet SRO transmitters and regulators for the measurement of Relative Humidity, Temperature, Atmospheric Pressure, and Carbon Dioxide.
Atmospheric Pressure Transmitters
T2114 Barometric Pressure Transmitter – 4-20mA Output
- Measuring range: 600 to 1100 hPa
- Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2118 Interior Barometer Transmitter with 4-20mA Output
- Measuring range: 600 to 1100 hPa
- Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2214 Barometric Pressure Transmitter – 0-10V Output
- Measuring range: 600 to 1100 hPa
- Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2218 Interior Barometer Transmitter with 0-10V Output
- Measuring range: 600 to 1100 hPa
- Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2314 Barometric Pressure Transmitter – RS232 Output
- Measuring range: 600 to 1100 hPa
- Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
T2414 Barometric Pressure Transmitter – RS485 Interface
- Measuring range: 600 to 1100 hPa
- Accuracy: ±1.3 hPa at 23 °C from 800 to 1100 hPa
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Relative Humidity, Temperature Transmitters and Regulators
H3020 temperature and humidity regulator
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3021 temperature and humidity regulator
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3021P compressed air temperature and humidity regulator
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3060 temperature and humidity regulator with 230Vac/8A relays, humidistat
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3061 temperature and humidity regulator with 230Vac/8A relays
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3061P compressed air temperature and humidity regulator with 230Vac/8A relays
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3331 temperature and humidity regulator with RS232 output
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3430 temperature and humidity regulator with RS485 output
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3431 temperature and humidity regulator with RS485 output
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3530 – thermometer hygrometer regulator with Ethernet interface and relays, humidistat
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531 – thermometer hygrometer regulator with Ethernet interface and relays
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531P – compressed-air thermometer hygrometer regulator with Ethernet interface and relays
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
H3531R – rack mount thermometer hygrometer regulator with Ethernet interface and relays
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3419P Compressed air RH+T transmitter with RS485 output
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
P1110E Economy humidity and temperature transmitter with 4-20mA outputs
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.6 °C; ±3 % RH from 5 to 95 % at 23 °C
P3116 Economy humidity and temperature transmitter with external interchangeable probe, 4-20mA outputs
- Measuring range: -20 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±1.8 % RH from 0 to 90 % at 23 °C
T0210 Temperature and humidity transmitter outdoor, indoor probe with 0-10V output
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0211 Temperature and humidity transmitter probe with 1m cable and 0-10V output
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0211P Compressed air RH+T+Tdp transmitter with 1m cable and 0-10V output
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0213 Temperature and humidity transmitter duct probe with 0-10V output
- Measuring range: -30 to +125 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T0213D Temperature and humidity transmitter duct probe with 0-10V output
- Measuring range: -30 to +125 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3110 Temperature and humidity transmitter outdoor, indoor probe with 4-20mA output
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3110Ex Intrinsically safe humidity and temperature transmitter with 4-20mA output
- Measuring range: -30 to +80 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111 transmitter RH+T+Tdp cable probe, 1m cable length, output 4-20mA
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111Ex Intrinsically safe humidity and temperature transmitter with cable probe, 1m cable length, output 4-20mA
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3111P transmitter compressed air RH+T+Tdp sensor with 4-20mA output
- Measuring range: -30 to +105 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113 Temperature and humidity transmitter duct probe with 4-20mA output
- Measuring range: -30 to +125 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113D Temperature and humidity transmitter duct probe with 4-20mA output
- Measuring range: -30 to +125 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3113Ex Intrinsically safe humidity and temperature transmitter duct transmitter with 4-20mA output
- Measuring range: -30 to +125 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3117 Temperature and humidity transmitter bar type probe with 4-20mA output
- Measuring range: -30 to +125 °C; 0 to 100 % RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C
T3118 Interior temperature, humidity transmitter with 4-20mA output
- Measuring range: -10 to +50 °C; 5 to 95% RH
- Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3218 Interior temperature, humidity transmitter with 0-10V output
- Measuring range: -10 to +50 °C; 5 to 95% RH
- Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3311 Temperature and humidity transmitter probe with RS232 output, internal sensors
- Measuring range: -30 to +80 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3313 Temperature and humidity transmitter probe with RS232 output
- Measuring range: -30 to +125 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3318 Interior temperature, humidity transmitter with RS232 output (Discontinued, Replaced by T3418)
- Measuring range: -10 to +50 °C; 5 to 95% RH
- Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T3319 Industrial temperature and humidity transmitter – RS232 output
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3411 RH+T+Tdp outdoor, indoor transmitter probe, RS485 interface
- Measuring range: -30 to +80 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3413 Temperature and humidity duct mount transmitter with RS485 output
- Measuring range: -30 to +125 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3413D Temperature and humidity duct mount transmitter with RS485 output
- Measuring range: -30 to +125 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3417 Temperature and humidity bar type transmitter with RS485 output
- Measuring range: -30 to +125 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3418 Interior temperature, humidity transmitter with RS485 output
- Measuring range -10 to +50 °C; 5 to 95 % RH
- Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 65 %
T3419 Temperature and humidity transmitter with external probe – RS485 output
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T3419P Compressed air RH+T transmitter with RS485 output
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Relative Humidity, Temperature and Atmospheric Pressure Transmitters And Regulators
H7430 temperature, humidity, pressure regulator with two relay and RS485 outputs
- Measuring range: -30 to +80 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7431 temperature, humidity, pressure regulator with two relay and RS485 outputs (Discontinued Model)
- Measuring range: Unavailable
- Accuracy: Unavailable
H7530 – thermometer hygrometer barometer regulator with Ethernet interface and relays
- Measuring range: -30 to +80 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7531 – thermometer hygrometer barometer regulator with Ethernet interface and relays
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
H7531R temperature, humidity and barometric pressure rack mount monitor (Discontinued Model)
- Measuring range: Unavailable
- Accuracy: Unavailable
T7310 Industrial temperature, humidity, bar. pressure transmitter – RS232 output
- Measuring range: -30 to +80 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7311 Industrial temperature, humidity, bar. pressure transmitter – RS232 output
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7318 Interior temperature, humidity, bar. pressure transmitter – RS232 output (Discontinued, Replaced by T3418)
- Measuring range: -10 to +50 °C; 0 to 100% RH
- Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
T7410 Industrial temperature, humidity, bar. pressure transmitter – RS485 output
- Measuring range: -30 to +80 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7411 Industrial temperature, humidity, bar. pressure transmitter – RS485 output
- Measuring range: -30 to +105 °C; 0 to 100% RH
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 %
T7418 Interior temperature, humidity, bar. pressure transmitter – RS485 output
- Measuring range: -10 to +50 °C; 0 to 100% RH
- Accuracy: ±0.5 °C; ±2.5 % RH from 5 to 60 %
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Temperature Transmitters and Regulators
H0430 temperature transmitter and regulator with RS485 output
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
H0530 – thermometer transmitter with Ethernet interface and relays
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
H4331 Temperature transmitter with RS232 output
- Measuring range: -200 to +600 °C
- Accuracy: ±0.2 °C
H4431 Temperature transmitter with RS485 output
- Measuring range: -200 to +600 °C
- Accuracy: ±0.2 °C
H4531 – thermometer transmitter with Ethernet interface and relays
- Measuring range: -200 to +600 °C
- Accuracy: ±0.2 °C
H4531R – rack mount thermometer with Ethernet interface and relays
- Measuring range: -200 to +600 °C
- Accuracy: ±0.2 °C
P0120 – Remote temperature sensor transmitter with 4-20mA output
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
P0132 – Duct mount temperature transmitter probe 0 to +150°C, IP65
- Measuring range: 0 to +150 °C
- Accuracy: ±0.4 °C
P4121 Temperature Transmitter Pt1000 -30°C to +80°C/ 4 to 20 mA
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
P4131 Temperature transmitter Transducer Pt1000 0°C to +150°C/ 4 to 20 mA
- Measuring range: 0 to +150 °C
- Accuracy: ±0.4 °C
P4141 Temperature transmitter Transducer Pt1000 -100°C to +30°C/ 4 to 20 mA
- Measuring range: -100 to +30 °C
- Accuracy: ±0.3 °C
P4151 Temperature transmitter Transducer Pt1000 0°C to +35°C/ 4 to 20 mA
- Measuring range: 0 to +35 °C
- Accuracy: ±0.2 °C
P4161 Temperature transmitter Transducer Pt1000 0°C to +250°C/ 4 to 20 mA
- Measuring range: 0 to +250 °C
- Accuracy: ±0.4 °C
P4171 Temperature transmitter Transducer Pt1000 0°C to +400°C/ 4 to 20 mA
- Measuring range: 0 to +400 °C
- Accuracy: ±0.7 °C
P4191 Temperature Transmitter Transducer Pt1000 -50°C to +50°C/ 4 to 20 mA
- Measuring range: -50 to +50 °C
- Accuracy: ±0.4 °C
P6181 Temperature Transmitter Transducer Pt100 -100°C to +200°C/ 4 to 20 mA
- Measuring range: -100 to +200 °C
- Accuracy: ±0.3°C up to +100°C, ±0.4°C over +100°C
T0110 Temperature transmitter outdoor, indoor with 4-20mA output
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
T4411 Temperature transmitter with RS485 interface
- Measuring range: -200 to +600 °C
- Accuracy: ±0.2°C (without temperature probe)
T0118 Interior temperature transmitter with 4-20mA output
- Measuring range: -10 to +50 °C
- Accuracy: ±0.5 °C
T0218 Interior temperature transmitter with 0-10V output
- Measuring range: -10 to +50 °C
- Accuracy: ±0.5 °C
T0310 Temperature transmitter with RS232 output
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
T0318 Interior temperature transmitter with RS232 output (Discontinued, Replaced by T0418)
- Measuring range: -10 to +50 °C
- Accuracy: ±0.5 °C
T0410 Temperature transmitter with RS485 output
- Measuring range: -30 to +80 °C
- Accuracy: ±0.4 °C
T0418 Interior temperature transmitter with RS485 output
- Measuring range: -10 to +50 °C
- Accuracy: ±0.5 °C
T4111 Temperature transmitter with 4-20mA output
- Measuring range: -200 to +600 °C
- Accuracy: ±0.15°C plus 0.1% from adjusted output span (without temperature probe)
T4211 Temperature transmitter with 0-10V output
- Measuring range: -200 to +600 °C
- Accuracy: ±0.15°C plus 0.1% from adjusted output span (without temperature probe)
T4311 Temperature transmitter with RS232 interface
- Measuring range: -200 to +600 °C
- Accuracy: ±0.2°C (without temperature probe)
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Carbon Dioxide Transmitters and Regulators
H5021 CO2 concentration transmitter with two relay outputs
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5024 CO2 concentration transmitter with two relay outputs
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5321 CO2 concentration transmitter with RS232 and two relay outputs
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5324 CO2 concentration transmitter with RS232 and two relay outputs
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5421 CO2 concentration transmitter with RS485 and two relay outputs
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5424 CO2 concentration transmitter with RS485 and two relay outputs
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
H5521 – remote Transmitter CO2 concentration with Ethernet interface and two relays
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
H5524 – remote Transmitter CO2 concentration with Ethernet interface and two relays
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5140 CO2 concentration transmitter with 4-20mA output, built-in carbon dioxide sensor
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5141 CO2 concentration transmitter with 4-20mA output, external carbon dioxide probe, 1m cable
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5240 CO2 concentration transmitter with 0-10V output, built-in carbon dioxide sensor
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5241 CO2 concentration transmitter with 0-10V output, external carbon dioxide probe, 1m cable
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5340 CO2 concentration transmitter with RS232 interface, internal carbon dioxide sensor
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5341 CO2 concentration transmitter with RS232 interface, external carbon dioxide probe, 1m cable
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
T5440 CO2 concentration transmitter with RS485 interface
- Measuring range: 0 to 2000 ppm
- Accuracy: ±(50ppm +2% from reading) at 25°C and 1013hPa
T5441 CO2 concentration transmitter with RS485 interface, external carbon dioxide probe, 1m cable
- Measuring range: 0 to 10 000 ppm
- Accuracy: ±(100ppm +5% from reading) at 25°C and 1013hPa
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Carbon Dioxide, Relative Humidity and Temperature Transmitters
H6020 Temperature, humidity, CO2 transmitter with two relay outputs
- Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6320 Temperature, humidity, CO2 transmitter with two relay and RS232 outputs
- Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6420 Temperature, humidity, CO2 transmitter with two relay and RS485 outputs
- Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
H6520 – remote Transmitter CO2 concentration thermometer hygrometer with Ethernet interface and two relays
- Measuring range: -30 to +80 °C; 0 to 100 % RH; 0 to 2000 ppm
- Accuracy: ±0.4 °C; ±2.5 % RH from 5 to 95 % at 23 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6340 Temperature, humidity, CO2 transmitter with RS232 interface
- Measuring range: -10 to +50 °C; 5 to 95 % RH; 0 to 2000 ppm
- Accuracy: ±0.5 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa
T6440 Temperature, humidity, CO2 transmitter with RS485 interface
- Measuring range: -10 to +50 °C; 5 to 95 % RH; 0 to 2000 ppm
- Accuracy: ±0.5 °C; ±2.5 % RH; ±(50ppm +2% from reading) at 25°C and 1013hPa
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!
Carbon Dioxide and Temperature Transmitters
T8148 CO2 concentration and temperature transmitter with 4-20mA outputs, built-in sensors
- Measuring range: -10 to +50 °C; 0 to 2000 ppm
- Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T8248 CO2 concentration and temperature transmitter with 0-10V outputs, built-in sensors
- Measuring range: -10 to +50 °C; 0 to 2000 ppm
- Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
T8448 CO2 concentration and temperature transmitter with RS485 output, built-in sensors
- Measuring range: -10 to +50 °C; 0 to 2000 ppm
- Accuracy: ±0.5 °C; ±(50ppm +2% from reading) at 25°C and 1013hPa
INTERESTED OR HAVE QUESTIONS? GET IN TOUCH WITH US NOW!